Search results
Jump to navigation
Jump to search
Page title matches
- === GFT Spins in Residue Definitions === I had to modify the residue definitions to get GFT spins displayed for (4,3)D HCCH-COSY spectra in SystemScope. Sum and differ3 KB (386 words) - 22:46, 9 November 2009
- === '''Analysis of the(4,3)D GFT HABCAB(CO)NHN''' === ...lored according to type of sub-spectrum and type of proton involved in the GFT dimension.4 KB (615 words) - 18:07, 1 December 2009
- == Picking Spins in (4,3)D GFT HNNCABCA and CABCA(CO)NHN Spectra == Open (4,3)D GFT HNNCABCA and CABCA(CO)NHN in SynchroScope as you did with 3D HNCO. You can5 KB (893 words) - 02:16, 9 December 2009
Page text matches
- ##GFT-based spectra ###GFT-based spectra893 bytes (120 words) - 16:21, 5 January 2010
- === GFT Spins in Residue Definitions === I had to modify the residue definitions to get GFT spins displayed for (4,3)D HCCH-COSY spectra in SystemScope. Sum and differ3 KB (386 words) - 22:46, 9 November 2009
- ...e same things as described in analysis of the [[HNCACAB/CABCA(CO)NH|(4,3)D GFT HNNCABCA and CABCA(CO)NHN]] spectra: <br>731 bytes (111 words) - 21:41, 30 November 2009
- ! GFT protocol *(3,2)D GFT HN<u>NCO</u> or 3D HNCO<br>2 KB (377 words) - 11:07, 8 January 2010
- ==== GFT Template ==== *[[Media:BoR54_template.cara|BoR54_template.cara]]: Latest GFT template for BoR54 project2 KB (301 words) - 22:38, 9 November 2009
- *[[GFT Spectra Parameters in CARA|Additional Parameters for GFT Spectra]] GFT template example4 KB (544 words) - 19:27, 9 December 2009
- The minimum measurement time of (4,3)D GFT experiments can be reliably predicted from the S/N distribution of a 2D [15 ...alue of 2 in order to be observed or detected, and the average b for (4,3) GFT experiments is 0.8; if 95% peak detection yield is required, the expected S4 KB (759 words) - 15:47, 15 December 2009
- === '''Analysis of the(4,3)D GFT HABCAB(CO)NHN''' === ...lored according to type of sub-spectrum and type of proton involved in the GFT dimension.4 KB (615 words) - 18:07, 1 December 2009
- ...Resonance_Assignment/CARA/Backbone_assignment_GFT|backbone assignment with GFT spectra]]996 bytes (125 words) - 20:13, 8 August 2012
- ...GFT NMR experiments, that is, HNNCABCA and CABCA(CO)NHN, or using two non-GFT experiments [[HNCACB/CBCA(CO)NH|HNNCACB/CACBCONHN]]. === '''Analysis of the (4,3)D GFT HNNCABCA and CABCA(CO)NHN spectra''' ===10 KB (1,722 words) - 21:29, 30 November 2009
- == Picking Spins in (4,3)D GFT HNNCABCA and CABCA(CO)NHN Spectra == Open (4,3)D GFT HNNCABCA and CABCA(CO)NHN in SynchroScope as you did with 3D HNCO. You can5 KB (893 words) - 02:16, 9 December 2009
- ...<span class="WYSIWYG_TT">SRD</span> for reduced dimensionality spectra and GFT spectra. The sequence file will contain only the residue type and the resid1 KB (165 words) - 17:09, 10 November 2009
- ==== '''Analysis of the (3,2)D GFT HNNCO spectrum''' ==== ...<tt>make32DHncoPeak</tt> in [[UBNMR|UBNMR]] (see below) to create a (3,2)D GFT HNNCO peaklist.6 KB (1,079 words) - 18:33, 24 November 2009
- ..., and epsilon ε.'' ''Dimensions of HCCH are w1, 13C;'' _w2, (13C+-1H), the GFT dimension;_ ''and w3, 1H, direct detect dimension.'' <br> <br> ...in the order of residue sequence (Figure 1). <br> '''Figure 1. Example of GFT (4,3)D HCCH analysis.''' Side by side [w2(13C;1H),w3(1HA)]-strip view of (412 KB (2,193 words) - 22:50, 11 November 2009
- ...rmission. AGNuS is also capable of processing reduced dimensionality/GFT experiments. === '''Processing a GFT Experiment Using AGNuS''' ===11 KB (1,457 words) - 15:57, 5 October 2011
- ##G-Matrix Fourier transformation (GFT) ...and HB Assignment with CARA|Assignment of HA and HB Resonances with (4,3)D GFT HABCAB(CO)NHN]]10 KB (1,271 words) - 20:51, 14 December 2009
- ...such as draft assignments (e.g. '?HA'), projected spins (e.g. 'HA-1') and GFT pseudospins (e.g. 'CApCB'). Bulk remove is possible with scripts such as Re2 KB (286 words) - 19:35, 18 October 2011
- ...for GFT spectra [[Media:BoR54_template.cara|BoR54_template.cara]]: Latest GFT template for BoR54 project7 KB (1,150 words) - 19:23, 9 December 2009
- ...s, lowercase letters "p" and "m" should be used instead for spin labels in GFT spectra. For example, sequential CA+CB peak should be labeled CApCB-1.6 KB (981 words) - 21:54, 16 November 2017
- .../sup>N resonance assignments using either conventional triple resonance or GFT approaches.7 KB (1,007 words) - 21:18, 6 January 2010