== '''Spin System Identification with CARA''' ==
== '''Spin System Identification with CARA''' ==


Spin system identification in 2D [15N,1H]-HSQC and 3D HNCO
Spin system identification in 2D [15N,1H]-HSQC and 3D HNCO  


# Open a repositiry or create one if it does not exist (see the CARA page).
#Open a repositiry or create one if it does not exist (see the CARA page).  
# Open 2D [15N,1H]-HSQC in SynchroScope to determine the region with true peak region and noise level.
#Open 2D [15N,1H]-HSQC in SynchroScope to determine the region with true peak region and noise level.  
# Run Lua script '''Pick_2D_Peaks'''. This script should be in the repository, otherwise get it from http://www.cara.ethz.ch/Wiki/AllCaluaScripts . '''Pick_2D_Peaks''' is equivalent to the <tt>in</tt> command in XEASY, but is not interactive. The script will create spin systems and populate them with H and N spins. Note that in CARA spin systems are distinct from residues and can have numbers starting with 1.
#Run Lua script '''Pick_2D_Peaks'''. This script should be in the repository, otherwise get it from http://www.cara.ethz.ch/Wiki/AllCaluaScripts . '''Pick_2D_Peaks''' is equivalent to the <tt>in</tt> command in XEASY, but is not interactive. The script will create spin systems and populate them with H and N spins. Note that in CARA spin systems are distinct from residues and can have numbers starting with 1.  
# To delete unwanted spin systems in SynchroScope use '''right click -> Delete Systems'''. To pick additional spin systems use '''right click -> Pick System'''
#To delete unwanted spin systems in SynchroScope use '''right click -&gt; Delete Systems'''. To pick additional spin systems use '''right click -&gt; Pick System'''  
# Open 3D HNCO in the strip panels of SynchroScope by using '''Strips -> Select Spectrum''' or '''right click -> Select Spectrum'''  
#Open 3D HNCO in the strip panels of SynchroScope by using '''Strips -&gt; Select Spectrum''' or '''right click -&gt; Select Spectrum'''  
# Select a spin system by left-clicking in HSQC plane or using '''View -> Goto System''' - this updates the strip display.
#Select a spin system by left-clicking in HSQC plane or using '''View -&gt; Goto System''' - this updates the strip display.  
# In the strip panel set the cursor on a peak and use '''right click -> Pick Label...''' or '''right click -> Pick Spin''' and '''right click -> Label Spin''' to pick C-1. Repeat last two steps for all spin systems.
#In the strip panel set the cursor on a peak and use '''right click -&gt; Pick Label...''' or '''right click -&gt; Pick Spin''' and '''right click -&gt; Label Spin''' to pick C-1. Repeat last two steps for all spin systems.


Also see instructions on how to use SynchroScope here:
Also see instructions on how to use SynchroScope here: http://www.cara.ethz.ch/Wiki/SynchroScope  
http://www.cara.ethz.ch/Wiki/SynchroScope


%COMMENT%




<br>


 
<br>-- Main.AlexEletski - 06 Jul 2007
-- Main.AlexEletski - 06 Jul 2007

Latest revision as of 17:15, 6 November 2009

Spin System Identification with CARA

Spin system identification in 2D [15N,1H]-HSQC and 3D HNCO

  1. Open a repositiry or create one if it does not exist (see the CARA page).
  2. Open 2D [15N,1H]-HSQC in SynchroScope to determine the region with true peak region and noise level.
  3. Run Lua script Pick_2D_Peaks. This script should be in the repository, otherwise get it from http://www.cara.ethz.ch/Wiki/AllCaluaScripts . Pick_2D_Peaks is equivalent to the in command in XEASY, but is not interactive. The script will create spin systems and populate them with H and N spins. Note that in CARA spin systems are distinct from residues and can have numbers starting with 1.
  4. To delete unwanted spin systems in SynchroScope use right click -> Delete Systems. To pick additional spin systems use right click -> Pick System
  5. Open 3D HNCO in the strip panels of SynchroScope by using Strips -> Select Spectrum or right click -> Select Spectrum
  6. Select a spin system by left-clicking in HSQC plane or using View -> Goto System - this updates the strip display.
  7. In the strip panel set the cursor on a peak and use right click -> Pick Label... or right click -> Pick Spin and right click -> Label Spin to pick C-1. Repeat last two steps for all spin systems.

Also see instructions on how to use SynchroScope here: http://www.cara.ethz.ch/Wiki/SynchroScope




-- Main.AlexEletski - 06 Jul 2007