Setting up non-uniformly sampled spectra: Difference between revisions

From NESG Wiki
Jump to navigation Jump to search
(Created page with 'This section describes the acquisition of non-uniformly sampled (NUS) 3D data tailored to subsequent processing with Multidimensional Decomposition (MDD) software, described else…')
 
No edit summary
Line 1: Line 1:
This section describes the acquisition of non-uniformly sampled (NUS) 3D data tailored to subsequent processing with Multidimensional Decomposition (MDD) software, described elsewhere on this site ([[Processing non-uniformly sampled spectra with Multidimensional Decomposition|Click here to read about the processing with MDD]]). The intention of recoding NUS data is to either speed up the acquisition for high sensitivity experiments and/or concentrated samples, or to increase resolution for other cases.  The package is available for academic users. Please contact Aleks Gutmanas ([[Mailto:agutmana@uhnres.utoronto.ca|agutmana@uhnres.utoronto.ca]]) to obtain your copy.  
This section describes the acquisition of non-uniformly sampled (NUS) 3D data tailored to subsequent processing with Multidimensional Decomposition (MDD) software, described elsewhere on this site ([[Processing non-uniformly sampled spectra with Multidimensional Decomposition|Click here to read about the processing with MDD]]). The intention of recoding NUS data is to either speed up the acquisition for high sensitivity experiments and/or concentrated samples, or to increase resolution for other cases.  The package is available for academic users. Please contact Aleks Gutmanas ([[Mailto:agutmana@uhnres.utoronto.ca|agutmana@uhnres.utoronto.ca]]) to obtain your copy.  


[[NUS giude for Varian|Setting up NUS spectra on Varian spectrometers with BioPack]]
[[NUS guide for Varian|Setting up NUS spectra on Varian spectrometers with BioPack]]  


[[NUS guide for Bruker according to Arrowsmith group in Toronto|Setting up NUS spectra on Bruker spectrometers]] according to the practice in the Arrowsmith group (University Health Network and University of Toronto)
[[NUS guide for Bruker according to Arrowsmith group in Toronto|Setting up NUS spectra on Bruker spectrometers]] according to the practice in the Arrowsmith group (University Health Network and University of Toronto)

Revision as of 19:03, 23 November 2009

This section describes the acquisition of non-uniformly sampled (NUS) 3D data tailored to subsequent processing with Multidimensional Decomposition (MDD) software, described elsewhere on this site (Click here to read about the processing with MDD). The intention of recoding NUS data is to either speed up the acquisition for high sensitivity experiments and/or concentrated samples, or to increase resolution for other cases.  The package is available for academic users. Please contact Aleks Gutmanas ([[1]]) to obtain your copy.

Setting up NUS spectra on Varian spectrometers with BioPack

Setting up NUS spectra on Bruker spectrometers according to the practice in the Arrowsmith group (University Health Network and University of Toronto)