Search results

Jump to navigation Jump to search
  • ...unlikely case that your template does not contain this script, you can get it here: [http://www.cara.ethz.ch/Wiki/CALUA http://www.cara.ethz.ch/Wiki/CALU ...e produced by UBNMR, but you will need to remove all SRD spin systems from it.
    977 bytes (164 words) - 22:40, 9 November 2009
  • ...gs that these professional Wikipedia writers have which makes them good at it. ...things but if you lack in this your content would probably be of no use as it will get deleted too soon. Wikipedia has notability and content requirement
    2 KB (387 words) - 17:18, 14 September 2018
  • ...bilities of false information in the pages monitor this website regularly. It might be an open source platform but there are a few restrictions to know a ...concise yet authentic and if there are any aspects of self-promotion then it never goes to the approval stage.
    2 KB (392 words) - 19:31, 14 September 2018
  • ...onines, the assignment strategy described below takes a "manual" approach. It is also recommended to obtain aliphatic side-chain assignment before pursui ...og window, type the 13C chemical shift of one of the methyl groups. (NOTE: it is important to type the chemical shift in as "17.65p" to indicate ppm. If
    2 KB (359 words) - 16:07, 18 December 2009
  • Here are a few easy steps that can help you become an expert Wikipedia editor. ...it is necessary for everyone to know most about the Wikipedia. Apparently, it is difficult for anyone to know absolutely everything about Wikipedia or as
    3 KB (490 words) - 15:06, 14 September 2018
  • *First, the peakIndex is checked. if it is less than the reserve number, the peak assignment from the ''original'' ...B, the protlist is checked to see if HB is valid for this residue, if not, it becomes QB.
    4 KB (684 words) - 20:05, 4 November 2009
  • ...-and-how-is-it-affecting-phone-repair Laser Separation Machine] And How Is It Affecting Phone Repair? == ...are curious about what a laser separator is. Is it easy and simple to use it to repair a broken screen on a mobile phone? Especially for some novices, t
    6 KB (949 words) - 03:39, 16 May 2021
  • #Open a repositiry or create one if it does not exist (see the CARA page). ...''Pick_2D_Peaks'''. This script should be in the repository, otherwise get it from http://www.cara.ethz.ch/Wiki/AllCaluaScripts . '''Pick_2D_Peaks''' is
    1 KB (258 words) - 17:15, 6 November 2009
  • ...frequency-domain data in the repository due to their large size. Instead, it stores paths to the corresponding files. ...nce you successfully provide the new path a spectrum, CARA will try to use it to read the remaining spectra. If all you spectra are in one place, you onl
    4 KB (562 words) - 20:25, 6 November 2009
  • ...the water line. Since the presence of long-range correlation is not known it may lead to overestimated peak integrals and too tight UPLs. To resolve these issues it may be suggested to run two automatic structure calculations, one with intr
    3 KB (360 words) - 21:11, 6 January 2010
  • ...d on particular software packages and particular selection of experiments. It will also describe a few tricks and shortcuts that are useful and save the
    649 bytes (92 words) - 21:16, 1 December 2009
  • It is helpful to have an estimation of the protein concentration obtained from #chemical shifts dispersion upfield of 0 ppm is good, since it indicates methyl protons that are in a folded core and nearby to methyl gro
    1 KB (250 words) - 19:39, 16 November 2009
  • ...ed in the r.f. coil region inside the NMR probe. This can be done with the help of a sample gauge, which usually has a center line and rectangular markings ...of a series of identical samples. Setting a sample tube too low may cause it to break, as well as contaminate and damage the probe!
    3 KB (613 words) - 16:08, 9 December 2009
  • ...m tuning and matching of a probe you have to re-cable the probe to connect it to the tuning bridge. The tuning bridge has a monitor displaying the amount #Disconnect it from the filter and connect it to the '''J5321''' port on the tune interface
    7 KB (1,216 words) - 23:22, 4 December 2009
  • * Try to reboot the spectrometers as shown in the pictures below when it is necessary.
    597 bytes (97 words) - 11:24, 8 January 2010
  • **Expand the region around it and use <tt>nl</tt> and <tt>movetof</tt> to shift 1H carrier to the peak ma **Expand the region around it and use 'calibrate' to set this point to 0 ppm.
    5 KB (774 words) - 18:36, 11 November 2009
  • ...S''' carbon is taken from another. With low-level fractional 13C-labeleing it is extremely unlikely that both glucose molelules are 13C-labeled. Therefor * 42 ms HSQC is rather insensitive and is optional. It is useful under conditions of severe overlap of methyl groups, when peaks o
    3 KB (532 words) - 20:11, 8 August 2012
  • ...rscience.wiley.com/cgi-bin/fulltext/113510727/PDFSTART a recent MRC paper] it has been reported that radiation damping can significantly affect the accur In the range 0-50 °C it can be linearized to
    5 KB (838 words) - 11:01, 8 January 2010
  • ...cope that can be used to open a spectrum without creating a project first. It is usually used for: See it description here: [http://www.cara.ethz.ch/Wiki/MonoScope http://www.cara.e
    8 KB (1,259 words) - 22:47, 9 November 2009
  • In order to correctly interpret NOESY data during structure determination it is necessary to know the oligomerization state of the protein at NMR condit
    787 bytes (109 words) - 16:33, 6 January 2010