Search results
Jump to navigation
Jump to search
- ...with MDD]]). The intention of recoding NUS data is to either speed up the acquisition for high sensitivity experiments and/or concentrated samples, or to increas1,018 bytes (144 words) - 12:39, 26 July 2010
- [[Media:AlexEletsky_NESG_Wiki_NMRacq.pptx|NESG Wiki: NMR data acquisition (Alexander Eletsky)]] [[Media:HsiauWei-Wiki-Data-Processing.ppt|NESG Wiki: NMR data processing (Hsiau-Wei Lee)]]1 KB (147 words) - 17:34, 6 January 2019
- === Acquisition of 1D <sup>15</sup>N T<sub>1</sub> and T<sub>2</sub> on Bruker Spectrometer ...D <sup>15</sup>N relaxation spectra by using the following settings in the acquisition mode:5 KB (854 words) - 21:36, 16 December 2009
- ...<span class="mw-headline">Setting up acquisition of non-uniformly sampled data on Varian spectrometers with BioPack </span> === ...hedule generator once again, otherwise you will not be able to process the data properly.4 KB (603 words) - 15:59, 15 December 2009
- == NMR Data Acquisition == *NMR data acquisition for protein structure determination6 KB (647 words) - 02:29, 29 November 2022
- ...Arrowsmith group in Toronto|click here for the Arrowsmith protocol for NUS data collection on Bruker instruments]]). Before the Multi-dimensional decomposition can be started, the raw data has to be converted through a number of steps to an appropriate format. The10 KB (1,525 words) - 12:54, 26 July 2010
- Processing of spectra at the console is routinely required during data collection. Here we describe some processing basics on Bruker spectro 1-Dimensional data sets are processed at the conclusion of the experiment using the command "f4 KB (623 words) - 16:51, 5 January 2010
- == '''Acquisition of NMR Data''' == Three types of data provide specific structural information about bound ligands:<br>7 KB (1,085 words) - 20:50, 6 January 2010
- ==== Considerations for best use of acquisition time<br> ==== The acquisition time for the indirect dimension of this J-mod method can be shorter than th9 KB (1,393 words) - 20:51, 18 December 2013
- == Setting up acquisition of non-uniformly sampled 3D spectra on Bruker spectrometers with TopSpin = ...presented in this window. The level of "sparsing" allows to fine tune the acquisition time. It should generally be 30% or more. T2sp parameters dictate the expon8 KB (1,249 words) - 16:56, 3 November 2010
- Data acquisition is taylored for [[Abacus|ABACUS]] approach for resonance assignment. Most 32 KB (377 words) - 11:07, 8 January 2010
- #When completed, replace the sample in the magnet. Either monitor the real data as it comes in or set up the experiment but run the first increment a numbe ...um and saved in two date-stamped text files in the local users <tt>vnmrsys/data/testlib</tt> directory and also plotted out in graphical form.4 KB (599 words) - 18:18, 12 February 2014
- Having processed 2D (15N, 1H) HSQC as described in data process, one can do the peak picking and integration of 2D (15N, 1H) HSQC m ...ram [[NESG:PeakintI|PeakintI]].<br> Type command: <br><br> <tt>peakintI ../data/NHsqc6001 nhsqcsa_b.peaks 250 -i -t 2 2 0.1 </tt><br><br> where the <tt>nhs4 KB (759 words) - 15:47, 15 December 2009
- == NMR Data Collection == #NMR data acquisition for protein structure determination10 KB (1,271 words) - 20:51, 14 December 2009
- ...quired for the purpose of protein structure validation and refinement. The data can be collected on samples labeled only with <sup>15</sup>N. Obtaining RDC === Data Acquisition and RDC Calculation ===11 KB (1,713 words) - 20:32, 18 December 2013
- '''NMR Data Processing > 2D HSQC-TROSY for RDCs Measurement''' <br> ...s applicable to proteins of small and moderate size (10-30 kDa). The acquisition time in the indirect t1 should be at least T2 of nitrogen. The measur12 KB (1,803 words) - 19:35, 17 August 2011
- #During data collection, post notes announcing that data acquisition for a potentially hazardous sample is on going ...ozen and stored at -80<sup>o</sup>C until needed for cryogenic probes data collection.<br>40 KB (6,261 words) - 16:14, 2 March 2012