Search results

Jump to navigation Jump to search

Page title matches

  • == '''Installing And Updating BioPack''' == ...ate is quicker, but it requires that you have the latest "base release" of BioPack installed
    1 KB (185 words) - 15:53, 15 December 2009

Page text matches

  • == '''Installing And Updating BioPack''' == ...ate is quicker, but it requires that you have the latest "base release" of BioPack installed
    1 KB (185 words) - 15:53, 15 December 2009
  • ...up acquisition of non-uniformly sampled data on Varian spectrometers with BioPack </span> === ...n-linear sampling according to V. Orekhov. If you have an older version of BioPack, please update to a more recent one.
    4 KB (603 words) - 15:59, 15 December 2009
  • ...correlates aromatic H-C protons of His with ring nitrogens. Modified from BioPack <tt>gNfhsqc.c</tt> by adding 90-180-90 composite 180 pulses on 15N and chan There is also the <tt>rna_WGgNhsqclr</tt> setup macro from BioPack. This macro loads the <tt>rna_WGgNhsqc.c</tt> pulsesequece with parameters
    2 KB (267 words) - 14:27, 7 October 2010
  • Modified from BioPack <tt>gnoesyCNhsqc.c</tt> by Main.AlexEletski, similar to the previous <tt>cn Requires pre-installed BioPack. BioPack power limits should be enabled on systems with cryogenic probes, otherwise
    3 KB (553 words) - 15:51, 15 December 2009
  • ...a/NUS guide for Varian|Setting up NUS spectra on Varian spectrometers with BioPack]]
    1,018 bytes (144 words) - 12:39, 26 July 2010
  • == Automated Calibration of 90° Pulse Widths (BioPack) == ...have to be calibrated for each sample to achieve maximum signal-to-noise. BioPack also provides tools, which automate the calibration of such parameters and
    10 KB (1,768 words) - 03:38, 3 September 2012
  • See 'Chapter 9.0: '''2H AutoCalibration'''' in the BioPack manual. The automatic calibration method of BioPack uses the same protein sample and calibrates the pulse directly on the HDO s
    11 KB (1,821 words) - 23:04, 5 January 2010
  • *BioPack manual Note that BioPack installation alters the interface described in the original manuals.
    8 KB (1,389 words) - 16:30, 9 December 2009
  • ...ing up non-uniformly sampled spectra/NUS guide for Varian|Guide for Varian/BioPack]] ###[[Installing and updating BioPack]]
    10 KB (1,271 words) - 20:51, 14 December 2009
  • **[[Installing and updating BioPack]]
    6 KB (647 words) - 02:29, 29 November 2022
  • *The standard BioPack pulse sequence <tt>ghbha_co_nh.c</tt> employs 1H multiplicity editing. Thus
    5 KB (893 words) - 02:16, 9 December 2009
  • The sequence is modified from the fast HSQC sequence (gNfhsqc) in Varian BioPack).<ref>Tjandra N. et al., JACS (1996), 118, 6364-72</ref><br>
    9 KB (1,393 words) - 20:51, 18 December 2013
  • ...tra can be collected either on Varian spectrometers with later versions of BioPack installed ([[Setting up non-uniformly sampled spectra/NUS guide for Varian|
    10 KB (1,525 words) - 12:54, 26 July 2010
  • ...ed below is specific for data collected on Varian spectrometers having the BioPack (version: 2009<span style="font: 12.0px Times New Roman">-0</span>9<span st
    12 KB (1,803 words) - 19:35, 17 August 2011